Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Rev. colomb. anestesiol ; 48(4): e204, Oct.-Dec. 2020. tab, graf
Article in English | LILACS, COLNAL | ID: biblio-1144315

ABSTRACT

Abstract Introduction: The use of ultrasound in regional anesthesia has become a standard technique to improve nerve block accuracy and reduce associated complications. The literature reports a good correlation between the distance from the skin to the dura mater or the ligamentum flavum measured on ultrasound and the conventional technique of "loss of resistance". Latin American populations have not been included in the studies conducted so far but, because of differences in physical build, it is important to determine whether this correlation is maintained in the various populations. This paper offers new information about the role of ultrasound in determining the distance to the ligamentum flavum and recognizing the proximity of the dura mater to avoid accidental puncture of this structure in Latin American populations. Objective: To determine correlation and concordance in estimating the distance from the skin to the epidural space between the loss of resistance technique and ultrasound measurement. Methodology: Observational study conducted in 52 pediatric patients who received general anesthesia plus epidural analgesia for acute perioperative pain management between July 2014 and November 2015 to assess correlation and concordance between loss of resistance and ultrasound measurement of distance to the epidural space. Results: There is a correlation between distances measured using the two techniques, which appears to be higher as patient age increases. As for concordance, the study found that 0.43 cm should be added to the ultrasound measurement to achieve agreement with the distance obtained using the loss of resistance technique; however, the interval between the two measurements is 1.15 cm. Conclusions: A correlation was found between the measurement taken from the skin to the epidural space using ultrasound and the measurement obtained with the traditional needle puncture and loss of resistance technique. Although concordance was not as expected and the distance measured with ultrasound may be smaller than the real measurement with the needle, ultrasound offers good guidance regarding proximity to the epidural space.


Resumen Introducción: El uso del ultrasonido en la anestesia regional se ha convertido en una técnica estándar para mejorar la precisión de los bloqueos nerviosos y disminuir las complicaciones relacionadas con dicha anestesia. La literatura informa que hay una buena correlación entre la distancia entre la duramadre o el ligamento amarillo y la piel según el ultrasonido y la técnica convencional de "pérdida de resistencia". Los estudios realizados hasta ahora no han incluido población latinoamericana y, debido a las diferencias en la contextura física, es importante determinar si esta correlación se mantiene en varias poblaciones. Con este trabajo se aporta nueva información sobre la utilidad del ultrasonido para determinar la distancia al ligamento amarillo y advertir la cercanía de la duramadre con el fin de evitar la punción accidental de esta estructura en población latina. Objetivo: Determinar la correlación y concordancia en la estimación de la distancia de la piel al espacio epidural entre la técnica de pérdida de resistencia y la medición por ultrasonido. Metodología: Se llevó a cabo un estudio observacional en 52 pacientes pediátricos, que recibieron anestesia general más analgesia epidural para manejo del dolor agudo perioperatorio entre julio de 2014 y noviembre de 2015. Se evaluó la correlación y la concordancia de la distancia medida al espacio epidural entre la técnica de pérdida de resistencia y la distancia por ultrasonido. Resultados: Existe una correlación entre la distancia obtenida mediante las dos técnicas de medición que parece aumentar a medida que aumenta la edad de los pacientes. En cuanto a la concordancia se encontró que a la medida tomada por ultrasonido se le debería sumar 0,43 cm para que concuerde con la distancia tomada por pérdida de resistencia; no obstante, el intervalo entre ambas medidas es de 1,15 cm. Conclusiones: Encontramos una correlación entre la medida tomada desde la piel hasta el espacio epidural por ultrasonido y la tomada por la técnica tradicional de punción con aguja y pérdida de resistencia. Aunque la concordancia que hallamos no fue la esperada, y la medición del ultrasonido puede ser menor a la medición real encontrada con la aguja, es una buena guía para advertir la cercanía del espacio epidural.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Adolescent , Analgesia, Epidural , Pediatrics , Skin , Ultrasonics , Ultrasonography , Epidural Space , Anesthesia, General , Nerve Block
2.
Rev. colomb. anestesiol ; 43(4): 269-277, Oct.-Dec. 2015. ilus, tab
Article in English | LILACS, COLNAL | ID: lil-767534

ABSTRACT

Introduction: The modified Wilson infraclavicular approach (MWIA) was described in our institution for brachial plexus blocks in paediatric patients. However, concordance studies between this approach and ultrasound for the identification of ideal puncture site have no been reported. Objective: To determine the concordance between MWIA and ultrasound for localization of the ideal puncture site. Materials and methods: Descriptive observational study; we included 100 healthy patients between 1 and 16 years of age, with parental consent, over a 5-month period. Continuous variables were described and kappa statistics were used for concordance evaluation. We also conducted a multivariate analysis to confirm the relationship between the measured distances and weight and height. Results: The distance fromthe skin to the brachial plexus, aswell as the distance between the coracoid process and the brachial plexus, and the distance from the coracoid process to the pleura were all smaller in abduction, with no statistically significant difference. Height and weight are independent factors that determine the distance between the coracoid process and the posterior cord, both in adduction and abduction. The concordance of MWIA vs. ultrasound for determining the ideal puncture site was 47% in both positions. Conclusions: Concordance between MWIA and ultrasound for the determination of the ideal puncture site is low when it comes to anatomic localization; however, this technique must be evaluated in randomized clinical studies in order to determine its efficacy and usefulness. Height and weight are independent factors that determine the distance between the coracoid process and the posterior cord in adduction and abduction.


Introducción: En pacientes pediátricos, el sitio óptimo de inyección para el abordaje infraclavicular sigue siendo sujeto de debate; no hay estudios de concordancia entre el abordaje infraclavicular de Wilson modificado para bloqueo del plexo braquial (AIWM) y el ultrasonido para la localización del sitio ideal de punción. Objetivo: Determinar la concordancia entre AIWM y ultrasonido para localizar el sitio ideal de punción. Materiales y métodos: estudio observacional descriptivo; se incluyeron 100 niños sanos entre 1-16 años, en un periodo de 5 meses. Se describieron variables continuas y se evaluó la concordancia mediante la estadística kappa. Se realizó análisis multivariado para confirmar la correlación entre las distancias, el peso y la talla. Resultados: Se encontró una menor profundidad del plexo braquial y menor distancia entre el plexo braquial y la apófisis coracoides y entre la coracoides y la pleura en abducción, sin significancia estadística. El peso y la talla son factores independientes que determinan la distancia entre la apófisis coracoides y el cordón posterior en abducción y en aducción. La concordancia del sitio ideal de punción entre AIWM y ultrasonido fue 0,47 en ambas posiciones. Conclusiones: La concordancia entre el AIWM y el ultrasonido para determinar el sitio ideal de punción es sorprendentemente baja. Sin embargo, desde el punto de vista de utilidad y eficacia clínica, estas técnicas deben ser comparadas y evaluadas con estudios clínicos aleatorizados. El peso y la talla determinan de forma independiente la distancia entre el cordón posterior y la apófisis coracoides en aducción y abducción del brazo.


Subject(s)
Humans
3.
Rev. colomb. anestesiol ; 40(4): 318-322, dic. 2012. ilus
Article in Spanish | LILACS, COLNAL | ID: lil-669158

ABSTRACT

Una de las lesiones más comunes en el grupo de cardiopatías congénitas es la hipoplasia del arco aórtico y la coexistencia de coartación aórtica en niños mayores, lo cual es de muy difícil manejo. Recientemente se describió una técnica para tratar esta patología que requiere extensas líneas de sutura y un preciso manejo de las alteraciones de coagulación asociadas con el empleo de circulación extracorpórea. Presentamos el caso de una niña de 8 años y 9 meses de edad con síndrome de Turner, coartación aórtica e hipoplasia de arco aórtico, que ingresó para plastia del arco por deslizamiento y que recibió terapia transfusional guiada mediante tromboelastografía.


One of the most frequent lesions in congenital heart disease is hypoplasia of the aortic arch and the co-existence of aortic coarctation in older children, which is very difficult to treat. A new technique for treating this condition was recently described and it requires extensive suture lines and an accurate management of coagulation disorders associated with the use of extracorporeal circulation. We present a case of an 8 years and 9 months old girl with Turner’s syndrome, aortic coarctation and aortic arch hypoplasia that was admitted for sliding arch aortoplasty and received thromboelastography guided transfusion therapy.


Subject(s)
Humans
4.
Rev. colomb. anestesiol ; 39(1): 119-127, feb.-abr. 2011. ilus, tab
Article in English, Spanish | LILACS | ID: lil-594567

ABSTRACT

Objetivo. Comparar la motilidad de la columna cervical durante la realización de laringoscopia directa utilizando hoja Miller con protección cervical, triple maniobra e intubación con estilete luminoso en pacientes sin predictores de vía aérea difícil. Métodos. Serie de casos de 5 pacientes femeninas sometidas a embolización electiva de malformaciones arteriovenosas cerebrales, entre enero y marzo de 2003, atendidas en el Hospital Universitario Fundación Santa Fe, de Bogotá. Se realizaron mediciones bajo videofluoroscopia para determinar el desplazamiento angular de la columna cervical. Resultado. Las 5 mujeres incluidas tenían una edad promedio de 43 años. Los puntos de mayor movimiento fueron C1 y C5. Se obtuvieron valores basales con la cabeza del paciente en posición neutra para comparar las demás mediciones. Se observó una menor movilidad en los puntos de mayor movimiento (C1 y C5) con la utilización del estilete luminoso, en comparación con la laringoscopia directa con hoja Miller (8° vs. 13,2° en C1, y 6,4° vs. 15,6° en C5). La realización de la triple maniobra y la fijación del tubo endotraqueal produjeron angulaciones menores, comparadas con las producidas durante las maniobra de intubación. Conclusión. La intubación con estilete luminoso podría ser una alternativa útil y segura en pacientes con trastornos de la columna cervical en quienes existen limitaciones para la movilización de ésta.


Objective. To compare the cervical spine motion with direct laryngoscopy using the Miller blade with cervical protection, triple maneuver and intubation with lightwand in patients with no predictors of a difficult airway.Methods. This is a series of 5 female patients who underwent elective embolization of cerebral arteriovenous malformations between January and March 2003, at the Fundación de Santa Fe University Hospital, Bogotá. Videofluoroscopic measurements were taken to determine the angular displacement of the cervical spine.Results. Rhe study included five female patients with an average age of 43 years. C1 and C5 were the segments with greater displacement. Baseline measurements were taken with the head of the patient in neutral position to compare against subsequent measurements. Less motion was observed at the segments with greater displacement (C1 y C5) with the use of the lightwand versus direct laryngoscopy with the Miller blade (8° vs. 13.2° at C1 and 6.4° vs. 15.6° at C5). The triple maneuver and the fixation of the endotracheal tube caused less angulation than the intubation maneuver. Conclusions. Lightwand intubation could be a useful and safe alternative in patients with cervical spine disorders and movement limitations.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Cervical Vertebrae , Fluoroscopy , Intubation , Laryngoscopy , Radiometry , Cervical Vertebrae , Fluoroscopy , Intubation , Laryngoscopy , Radiometry
SELECTION OF CITATIONS
SEARCH DETAIL